General Rubber Sheathed Flexible Cable

General Rubber Sheathed Flexible Cable
General rubber sheathed flexible cables are suitable for power transmission of power, household appliances, and various mobile outdoor electrical equipment and tools with AC rated voltage of 450/750V and below. Their mechanical properties comply with GB/T5013-2008 "Rubber Insulated Cables with Rated Voltage of 450/750V and Below" and JB/T8735-2016 "Rubber Insulated Flexible Wires and Cables with Rated Voltage of 450/750V and Below" standards.
+86 198 6198 9573
+86 198 6198 9573
Anita@frt-electric.com
Get A Quote

Product Description

General rubber sheathed flexible cables are suitable for power transmission of power, household appliances, and various mobile outdoor electrical equipment and tools with AC rated voltage of 450/750V and below. Their mechanical properties comply with GB/T5013-2008 "Rubber Insulated Cables with Rated Voltage of 450/750V and Below" and JB/T8735-2016 "Rubber Insulated Flexible Wires and Cables with Rated Voltage of 450/750V and Below" standards.


Use features

1. The rated AC voltage Uo/U: YQ and YQW cables are 300/300V; YZ, YZW, and 245IEC57 (YZW) cables are 300/500V; YC, YCW, and 245IEC66 (YCW) cables are 450/750V.

2. The long-term allowable working temperature of the cable core should not exceed 65 ℃.

3. The "W" type derived cable has weather resistance and certain oil resistance, making it suitable for use outdoors or in situations where it comes into contact with oil stains.

Model, name, and scope of production and use of cables

ModelProduct NameSpecification (mm²)Core CountApplication
YZ / 60245IEC53(YZ)Medium-duty rubber-sheathed flexible cables0.75~61, 2, 3, 4; 3+1, 3+2; 4+1, 5, 6, 8Used for various mobile electrical equipment, capable of withstanding general mechanical external forces.
YZW / 60245IEC57(YZW)Outdoor medium-duty rubber-sheathed flexible cables0.75~61, 2, 3, 4; 3+1, 3+2; 4+1, 5, 6, 8Used for various mobile electrical equipment, with weather and oil resistance, capable of withstanding general mechanical external forces.
YCHeavy-duty rubber-sheathed flexible cables1.5~400 (general); 1.5~95; 1.5~150; 1.5~25 (by application scenarios)1, 2, 3, 4; 3+1, 3+2; 4+1, 5Used for connecting various electrical equipment, capable of withstanding heavy mechanical external forces.
YCW / 60245IEC66(YCW)Outdoor heavy-duty rubber-sheathed flexible cables1.5~400 (general); 1.5~95; 1.5~150; 1.5~25 (by application scenarios)1, 2, 3, 4; 3+1, 3+2; 4+1, 5Used for various mobile electrical equipment, with weather and oil resistance, capable of withstanding heavy mechanical external forces.

Main electrical performance indicators of cables


1. Direct current resistance of conductor


The DC resistance of the conductor of a 20 ℃ cable complies with the provisions of GB/T3956-2008 "Conductors of Cables" standard

2. Power frequency AC voltage test


The cable should withstand the power frequency AC voltage test specified in the table below without breakdown

Test ItemSub-itemConditionRated Voltage 300/300VRated Voltage 300/500VRated Voltage 450/750V
1. Finished cable voltage testTest voltage (V)-200020002500

Minimum voltage application time (min)-555
2. Insulated core voltage testTest voltage (V)Insulation thickness ≤ 0.6mm15001500-


Insulation thickness ≥ 0.6mm200020002500

Minimum voltage application time (min)-555